How To Set Up A Co2 Keg Tap
This is a general reference guide for assembling and installing a standard full-size kegerator. Depending on the kegerator make, make, and model, slight modifications may be needed in the assembly and installation. Please be sure to refer to the user manual that comes with your specific model.
For a visual reference of parts that are numbered in parentheses in this installation guide, please view the kegerator diagram beneath.
Listed Parts:
- Faucet Handle
- Faucet
- Beer Tower
- Baby-sit Runway
- Baste Tray
- Regulator
- CO2 Tube
- CO2 Cylinder
- CO2 Holder
- Keg Coupler
- Metallic Keg Flooring Support
- Caster Washer (x2)
- Casters (x4)
- Neoprene Washer
- Snap-On Clamps (x2)
- Wire Shelves (not pictured) (x2)
- Half Barrel Keg (not included)
- Faucet Wrench (not pictured)
For a more than in-depth review of what each component is, please refer to our Kegerator Parts commodity.
Footstep-by-Step Instructions for Assembling Your Kegerator
Follow these step-by-step instructions for assembling your kegerator and installing/tapping a keg inside of it.
i. Install Pulley Wheels
Before beginning, make sure the unit is empty – including the white metal keg flooring (11). And then, carefully tip the beer dispenser on its side. Connect the casters (13) to the chiffonier by screwing in each metal bracket into one of four caster holes. The casters in the front of the cabinet crave the washers (12). When done, carefully set the unit upright.
2. Remove Plug
Open the door, and with your hand push the tiptop cabinet plug through the peak of the cabinet until it comes out. Alternately, you can apply a flat head screwdriver as a prying tool.
3. Install Tower
Now y'all can begin to install the draft tower (iii). Unravel the beer line hose from the bottom of the belfry, and feed the hex nut and beer line through the hole you lot uncovered in the top of the cabinet.
4. Secure Tower
Once you have fed all the line into the cabinet, you lot are ready to place the tower into the unit. Align the black plastic adapter on the bottom of the tower to the hole in the top of the cabinet. Once the adapter is deeply lined upward to the hole, plow the adapter about 25° clockwise to lock it into place. The faucet connection for the tower should now face up the front of the chiffonier, but if not remove it and reinstall from another position.
5. Install Railing
Take the railing (4) and place it'southward feet into the airplane pilot holes in the peak of the cabinet.
6. Install Handle Faucet
Spiral the blackness faucet handle (1) on to the faucet (2), then spiral the faucet onto the faucet adapter on the front of the tower (3). Make sure the faucet is vertical with the black handle facing the ceiling, and the faucet should be screwed on tightly. Place the plastic baste tray (v) below the faucet.
six. Connect Tube to Regulator
Cheque the switch beneath the main body to make certain the CO2 regulator (half dozen) shut off valve is airtight (the switch should be perpendicular to the tubing). Install the 4 ft. CO2 gas line tube (7) to the regulator past attaching one finish of the tube into the hose barb connection on the CO2 regulator and secure the tube by using i of the two self-locking red plastic snap-on clamps (xv). Use pliers or clamp crimpers to snap the clamp on as high as possible, and brand sure the clamp does not impede the valve. Then remove the black prophylactic plug from the dorsum of the unit of measurement and feed the remaining unused end of the tubing through the hole.
7. Connect Regulator to Cylinder
Make certain the CO2 cylinder (8) is total and closed. And then attach the CO2 regulator (six) to the cylinder by screwing the loose golden regulator nut into the cylinder valve and tightening with a wrench or pliers. Notation that a fiber washer is commonly required to connect a regulator to a CO2 cylinder, but a standard regulator more often than not includes a born O-ring.
8. Mountain CO2 Cylinder
Now mount the CO2 cylinder holder (9) to the cabinet. Match upwardly the holes on the holder with the screws jutting out of the back of the cabinet and slide the holder down to lock information technology in place. Position the CO2 regulator (6) in the holder then that you lot will be able to read the numbers on the gauge and have easy access to the close-off valve.
nine. Connect Keg Coupler
To connect the keg coupler (10) to the keg (17), first make sure the black pull handle of the keg coupler is in the airtight (diagonal/upper) position. Insert the keg coupler into the locking neck of the beer keg and turn clockwise 25° to lock in into place. At present the keg coupler is secured to the keg.
x. Attach Tube to Coupler
Now attach the remaining open up end of the CO2 gas line tube (7) to the keg coupler's hose affront (10). Then secure the tube by using the remaining self-locking red plastic snap-on clamp (15). Use pliers or clamp crimpers to snap the clamp securely as shut to the coupler equally possible.
11. Connect Beer Line to Coupler
Now connect the beer line from the tower (3) to the keg coupler. Insert the neoprene washer (14) into the beer line hex nut (the beer line is the line coming from the tower and faucet). Remove the blue condom protective cap located on top of the keg coupler and firmly spiral the nut with the neoprene washer to the top of the keg coupler.
12. Tap Keg
To secure the tank connection, pull the tap handle out — abroad from the keg coupler (10) — and push down until information technology locks into position. Listen for the "click" of the pull handle when information technology shifts into the final downward position, and your keg will exist tapped.
thirteen. Calibrate Regulator
Below are step-by-step instructions on how to calibrate your regulator. On the right, yous can see photos to illustrate the steps listed.
A:
With the shut-off valve on the regulator (vi) airtight, open the valve on the gas cylinder (8) completely.
B:
Loosen the aligning nut with a pair of pliers, allowing the adjustment screw to be turned counter-clockwise until the screw tin no longer turn.
C:
Slowly turn the regulator adjustment spiral until the desired pressure is shown on the output force per unit area gauge. Nether normal circumstances, we recommend setting the regulator at 12 PSI.
NOTE: Other conditions, such equally distance or special beer type, may crave some adjustment. On regulators designed for typhoon beer, turning clockwise will increase the output force per unit area, and turning counter-clockwise will decrease the output pressure level.
D:
Open up the shut-off valve on the regulator, ensuring the switch below the master body should be parallel to the tubing. Gas should now flow from the regulator to the keg coupler (10), and you will hear the keg pressurizing. The output needle will drib momentarily while the force per unit area is equalizing, and then it will return to the point at which yous fix information technology.
East:
The keg coupler is designed with a pressure relief valve (PRV). Pull the band on the PRV briefly to allow gas to vent. This will let gas to catamenia through the regulator and help obtain a more than authentic reading on the output pressure guess.
F:
Re-check the output pressure on the regulator and, if necessary, re-adjust using step B until the desired pressure is shown.
NOTE: It is e'er wise to follow upward whatever adjustment to the regulator with a brief pull of the PRV band to ensure an authentic output reading.
14. Position Keg & Enjoy!
Place the metallic keg floor support (11) back into the cabinet. Then, carefully tilt the beer keg (17) and rest the edge on the keg floor support on the lesser of the interior cabinet. Slide the keg in slowly, ensuring that it is properly located, and all hoses are articulate of obstructions. Close door and relish some refreshing draft beer!
That's Information technology!
At present that your keg is fully assembled and the keg is tapped, the only thing left to practice is enjoy a fresh draft beer correct in the comfort of your home. If you have any questions about assembling or installing your keg, please leave them in the comments below or requite us a phone call at one-866-950-8710.
How To Set Up A Co2 Keg Tap,
Source: https://learn.kegerator.com/assembly-guide/
Posted by: rountreehisis1968.blogspot.com

0 Response to "How To Set Up A Co2 Keg Tap"
Post a Comment